NYY-J 3/4/5 CORE
These cables are widely used for power and control for fixed wiring installations with a voltage rating of 600/1000V.
They can be safely deployed in most applications where mechanical stresses are not anticipated and are suitable for use indoors and outdoors. These black NYY cables have a UV-stabilised outersheath making them suitable for direct exposure to sunlight.
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
DoncasterCablesDatasheet (Classic)
Available Variations
| Name | Core Colours | Number of conductors | Conductor Size | Standard | Current Ratings | Voltage Rating | Approximate Weight (kg/km) | Details |
|---|---|---|---|---|---|---|---|---|
| NYY-J 3 CORE 1.5 BLACK | Green/Yellow, Blue, and Brown | 3 | 1.5 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 177 | View |
| NYY-J 3 CORE 2.5 BLACK | Green/Yellow, Blue, and Brown | 3 | 2.5 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 221 | View |
| NYY-J 3 CORE 4.0 BLACK | Green/Yellow, Blue, and Brown | 3 | 4 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 308 | View |
| NYY-J 3 CORE 6.0 BLACK | Green/Yellow, Blue, and Brown | 3 | 6 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 387 | View |
| NYY-J 3 CORE 10.0 BLACK | Green/Yellow, Blue, and Brown | 3 | 10 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 569 | View |
| NYY-J 3 CORE 16.0 BLACK | Green/Yellow, Blue, and Brown | 3 | 16 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 777 | View |
| NYY-J 4 CORE 1.5 BLACK | Green/Yellow, Brown, Black, and Grey | 4 | 1.5 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 215 | View |
| NYY-J 4 CORE 2.5 BLACK | Green/Yellow, Brown, Black, and Grey | 4 | 2.5 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 270 | View |
| NYY-J 4 CORE 4.0 BLACK | Green/Yellow, Brown, Black, and Grey | 4 | 4 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 380 | View |
| NYY-J 5 CORE 1.5 BLACK | Green/Yellow, Blue, Brown, Black, and Grey | 5 | 1.5 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 244 | View |
| NYY-J 5 CORE 2.5 BLACK | Green/Yellow, Blue, Brown, Black, and Grey | 5 | 2.5 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 311 | View |
| NYY-J 5 CORE 4.0 BLACK | Green/Yellow, Blue, Brown, Black, and Grey | 5 | 4 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 380 | View |
| NYY-J 5 CORE 6.0 BLACK | Green/Yellow, Blue, Brown, Black, and Grey | 5 | 6 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 568 | View |
| NYY-J 5 CORE 10.0 BLACK | Green/Yellow, Blue, Brown, Black, and Grey | 5 | 10 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 849 | View |
| NYY-J 5 CORE 16.0 BLACK | Green/Yellow, Blue, Brown, Black, and Grey | 5 | 16 | BS EN 60502-1 | For current ratings refer to table 4D2A and 4D2B of BS7671 IET Wiring Regulations. | 600/1000V | 1158 | View |
Dimensional Details
| Reference Number | Nominal Cross Sectional Area of Conductor (mm²) | Conductor Class to BS EN60228 | Nominal Thickness of Insulation (mm) | Nominal Radial Thickness of Insulation (mm) | Approximate Overall Diameter (mm) | Weight (Kg/Km) |
| NYY3C1.5 | 1.5 | Class 1 | 0.8 | 1.8 | 11.0 | 177 |
| NYY3C2.5 | 2.5 | Class 1 | 0.8 | 1.8 | 11.9 | 221 |
| NYY3C4.0 | 4.0 | Class 1 | 1.0 | 1.8 | 13.7 | 308 |
| NYY3C6.0 | 6.0 | Class 1 | 1.0 | 1.8 | 14.7 | 387 |
| NYY3C10 | 10.0 | Class 2 | 1.0 | 1.8 | 17.4 | 569 |
| NYY3C16 | 16.0 | Class 2 | 1.0 | 1.8 | 19.5 | 777 |
| NYY4C1.5 | 1.5 | Class 1 | 0.8 | 1.8 | 12.0 | 215 |
| NYY4C2.5 | 2.5 | Class 1 | 0.8 | 1.8 | 12.9 | 270 |
| NYY4C4.0 | 4.0 | Class 1 | 1.0 | 1.8 | 14.9 | 380 |
| NYY5C1.5 | 1.5 | Class 1 | 0.8 | 1.8 | 12.6 | 244 |
| NYY5C2.5 | 2.5 | Class 1 | 0.8 | 1.8 | 13.7 | 311 |
| NYY5C4.0 | 4.0 | Class 1 | 1.0 | 1.8 | 14.9 | 380 |
| NYY5C6.0 | 6.0 | Class 1 | 1.0 | 1.8 | 17.3 | 568 |
| NYY5C710 | 10.0 | Class 2 | 1.0 | 1.8 | 20.6 | 849 |
| NYY5C716 | 16.0 | Class 2 | 1.0 | 1.8 | 22.4 | 1158 |
| Weight and dimensional information is provided as an approximate guide only. | ||||||