PV-ULTRA 4 CORE

PV-ULTRA4C6.0

PV Ultra is a multicore DC solution that previously was solved by a multicore armoured cable. These multicore armoured cables are no longer recommended for use on the DC side of the installation. PV Ultra can now serve as a direct replacement allowing for a compliant multicore solution. The double insulated conductors are particularly suitable for use at the direct current (d.c.) side of the photovoltaic system, with a nominal d.c. voltage of 1.5kV between conductor and between conductor and earth. Due to the double insulation these cables are suitable to be used with Class II equipment (meeting the requirement of BS7671 Clause 712.412.101 which states that the electrical equipment up to the DC connection of the PV inverter shall be Class II or equivalent insulation) The double insulated conductors are enclosed in a CarbonTek® bedding, to give even more electrical protection against the steel wire armour (where applicable), with a final outer sheathing of SolarTek® PVC being applied to all variants of the cable (steel wire armoured or not)

SKU: PV-ULTRA4C6.0
Reference: 11838894
Product Group: PV-ULTRA 4C
Supplier: Doncaster Cables

No images available

Quick Facts


SKU
PV-ULTRA4C6.0
Reference
11838894
Product Group
PV-ULTRA 4C
Specifications
30

Technical Specifications

Number of conductors
4
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
90°C
Colour
Black
Core Colours
Red and White
Current Ratings
57A
Conductor Class to BS EN 60228
Class 5
Bullet1
Manufactured in the UK
Bullet2
Manufactured with 100% renewable energy
Bullet3
Uses materials and manufacturing techniques designed to make the electricians life easier
Bullet4
BASEC Approved
Unit
1000
Conductor Size
6.0
Construction
Tinned Annealed Copper Class 5 Flexible
Conductor
Tinned Annealed Copper Class 5 Flexible
Insulation
Double insulated cross-linked and fulfilling the requirements
Bedding
PVC CarbonTek Bedding
Sheathing
PVC UV resistant SolarTek
Voltage Rating
1500V max
Minimum Bending Radius
8 x diameter
Approximate Weight (kg/km)
715
Cable Types
Multicore Photovoltaic Cable
Nominal Overall Diameter of Bedding (mm)
17.0
Nominal Stranding of Conductor (mm)
84/0.3
Nominal Radial Thickness of Sheath (mm)
1.10mm
Nominal Radial Thickness of Bedding (mm)
0.5mm
Approximate Overall Diameter (mm)
19.40mm
Overall Diameter Lower Limit (mm)
18.95mm
Overall Diameter Upper Limit (mm)
19.80mm
Nominal Radial Thickness of Insulation (mm)
0.7mm